Features of 42H NEMA17 2Phase 1.8°
High output torque, high resolution, high-precision positioning, small vibration
Application for 42H NEMA17 2Phase 1.8°
Medical industry: Biochemical analyzer, blood cell analyzer
Advertising industry: Marking machine
Technical Parameter
Item | Specifications | |||
Step Angle Accuracy | ±5% (full step, no load) | |||
Resistance Accuracy | ±10% | |||
Inductance Accuracy | ±20% | |||
Temperature Rise | 80°C MAX.(rated current,2 phase on) | |||
Ambient Temperature | -10°C~+50°C | |||
Insulation Resistance | 100MΩMin.@ 500VDC | |||
Dielectric Strength | one minute @ 500VAC·5mA | |||
Shaft Radial Play | 0.06Max. @ 450g | |||
Shaft Axial Play | 0.08Max. @ 450g |
Technical Specification
Model No. | Polar | Rated Voltage | Current/Phase | Resistance/Phase | Inductance/Phase | Holding Torque | #Of leads | Rotor Inertia | Weight | Length | |
V | A | Ω | mH | oz-in | kg·cm | g·cm² | kg | mm | |||
42H033H-0504 | Bipolar | 4.5 | 0.425 | 10.5 | 18 | 29.2 | 2.1 | 4 | 35 | 0.22 | 33 |
42H033H-1334 | 2.8 | 1.33 | 2.1 | 2.5 | 33.3 | 2.4 | |||||
42H039H-1684 | 2.8 | 1.68 | 1.65 | 3.2 | 52.8 | 3.8 | 54 | 0.28 | 39 | ||
42H047H-1504 | 3.45 | 1.5 | 2.3 | 4.6 | 77.8 | 5.6 | 68 | 0.35 | 47 | ||
42H057H-1504 | 3.75 | 1.5 | 2.5 | 6.5 | 95.8 | 6.9 | 80 | 0.43 | 57 | ||
42H033H-0316 | Unipolar | 11.9 | 0.31 | 38.5 | 25 | 27.8 | 2 | 6 | 35 | 0.22 | 33 |
42H033H-0906 | 4 | 0.9 | 4.5 | 3.5 | 27.8 | 2 | |||||
42H039H-0406 | 12 | 0.4 | 30 | 30 | 43.1 | 3.1 | 54 | 0.28 | 39 | ||
42H039H-1206 | 4 | 1.2 | 3.3 | 3.2 | 43.1 | 3.1 | |||||
42H047H-0406 | 12 | 0.4 | 30 | 25 | 52.8 | 3.8 | 68 | 0.35 | 47 | ||
42H047H-1206 | 4 | 1.2 | 3.3 | 2.8 | 50 | 3.6 |